China Suppliers Factory: Versatile Shaft Seal for Glass Lined Reactor GM2010 with Double End Structure
Product Introduction
Operating Parameters
- Pressure: -0.1 ~ 1.6 MPa
⚠ When the pressure in the kettle is ≥ 0.4 MPa, a booster auxiliary system must be configured.
- Temperature: -40 ~ 180 ℃
⚠ When the temperature exceeds 180 ℃, the cooling water tank must be set up, and the height is increased by 80 mm.
Applicable Condition
Strong corrosive medium other than hydrofluoric acid.
Frequently Asked Questions
Q
What is the maximum operating pressure this equipment can handle?
The equipment supports a pressure range of -0.1 to 1.6 MPa. However, when the pressure inside the kettle reaches or exceeds 0.4 MPa, a booster auxiliary system must be installed to ensure safe and stable operation.
Q
What temperature range is this product designed for?
The product operates within a temperature range of -40 ℃ to 180 ℃. For applications exceeding 180 ℃, an additional cooling water tank must be configured, and the unit height increases by 80 mm.
Q
Why is a booster auxiliary system required at pressures ≥ 0.4 MPa?
At pressures of 0.4 MPa and above, the internal vessel stress increases significantly. A booster auxiliary system provides additional structural support and pressure management to maintain operational safety and equipment longevity.
Q
Can this equipment handle hydrofluoric acid?
No. This product is designed for strong corrosive media but explicitly excludes hydrofluoric acid. Please consult our engineering team for alternative solutions if hydrofluoric acid handling is required.
Q
What does the height increase of 80 mm mean in high-temperature configurations?
When operating above 180 ℃, a cooling water tank must be integrated into the system. This additional component adds 80 mm to the overall equipment height, which should be accounted for during installation planning and space allocation.
Q
What types of corrosive media is this product suitable for?
This product is suitable for a wide range of strong corrosive media, including acids and alkalis commonly used in chemical processing, with the exception of hydrofluoric acid. Its materials and design are optimized for corrosion resistance under the specified pressure and temperature conditions.