Introducing our innovative double end structure shaft seal, expertly designed for exceptional versatility and functionality. This product is particularly suitable for glass-lined reactors, allowing for a variety of material selections and end combinations to effectively meet diverse working conditions, The Type 2110 model features advanced bearings that enhance the stability of the mixing shaft, ensuring smooth operational performance and reliability. As a leading China factory and supplier, we are committed to delivering high-quality solutions tailored to your specific needs. Embrace superior sealing technology with our products, designed to achieve optimal efficiency in your industrial applications

    Product Introduction
    Pressure
    -0.1 ~ 1.6 MPa
    ⚠ When pressure ≥ 0.4 MPa, a booster auxiliary system must be configured.
    Temperature
    -40 ~ 180 ℃
    ⚠ When temperature exceeds 180 ℃, a cooling water tank must be set up, and height is increased by 80 mm.
    Applicable Condition
    Strong corrosive medium other than hydrofluoric acid.
    Frequently Asked Questions
    Q What is the maximum operating pressure supported?
    The equipment supports a pressure range of -0.1 to 1.6 MPa. However, when the pressure inside the kettle reaches or exceeds 0.4 MPa, a booster auxiliary system must be installed to ensure safe operation.
    Q Why is a booster auxiliary system required at 0.4 MPa or above?
    At pressures of 0.4 MPa or higher, the internal stress on the reactor vessel increases significantly. The booster auxiliary system is mandatory to maintain structural integrity and prevent operational failures or safety hazards.
    Q What happens when the operating temperature exceeds 180 ℃?
    When the temperature exceeds 180 ℃, a cooling water tank must be installed. This also requires increasing the overall equipment height by 80 mm to accommodate the additional cooling system.
    Q Which corrosive media is this equipment suitable for?
    The equipment is designed for use with strong corrosive media. It is applicable to a wide range of highly corrosive substances, with the exception of hydrofluoric acid, which is explicitly excluded.
    Q Can this equipment handle sub-zero temperatures?
    Yes. The operating temperature range starts at -40 ℃, making it suitable for cryogenic or low-temperature process environments, up to a maximum of 180 ℃ under standard configuration.
    Q Why is hydrofluoric acid excluded from the applicable conditions?
    Hydrofluoric acid has extremely aggressive chemical properties that can attack and degrade most common materials used in reactor vessel construction. Special-purpose equipment with compatible lining materials is required when handling hydrofluoric acid.